Features
• UL / CUR file: pending • TUV file: pending • 5A switching capabilities • 1 pole configurations • 2 KV dielectric coil to contacts • slim size (width 5 mm, height 12,5 mm) • sealed type available • high sensitivity 0,12 W
|
Coil Table
Nominal Voltage VDC: 24 Pickup Voltage VDC: 16 Dropout Voltage VDC: 1,20 Coil Current (at 20°C) mA: 7,50 Coil Resistance(at 20°C) Ohms +/- 10 %: 3200
|
|
General Data
Initial Insulation Resistance... 1000 MOhms (at 500 VDC) Dielectric Strength ......2000 VAC (between coil and contacts) 1000 VAC (between open contacts) Surge Voltage............ 4000 V (1,2 x 50 us) (between contacts and coil) Operate time (at nomi. Vot.) .. 6 ms Release time (at nomi. Vot.)... 3 ms Temperature rise (at nomi. Vot.)........................ 45°C Shock Resistance............ Functional 147 m/s2 Destructive 980 m/s2 Vibration Resistance.............. 10–55 Hz double amplitude 2.5 mm Humidity .............. ......... 5 % – 85 % Ambient temperature ............ -40°C – 70°C Unit weight ........................... 3 g Construction.......................... sealed Expected life min ops............ Mechanical 2 x 107 ops (72000 ops/h) Electrical 1 x 105 ops (360 ops/h)
|
Contact Data
1: single contact 1 pole Arrangement...................... 1A Initial Contact Resistance ...... 50 mOhms Contact Material................. Silver alloy Contact Rating (res. Load)..... 3 A, 250 VAC / 30 VDC Max. switching voltage ......... 250 VAC, 110 VDC Max. switching current.......... 5 A Max. switching power ....... 750 VA / 90 W UL/CUR rating ............... 3 A, 250 VAC / 30 VDC, 1 x 105 ops 5 A, 250 VAC / 30 VDC, 5 x 104 ops TUV rating................... 3 A, 250 VAC / 30 VDC, 1 x 105 ops 5 A, 250 VAC / 30 VDC, 5 x 104 ops Nominal coil Power ......... 0,12 – 0,18 W
|